careers icon
23 73 00

Indoor Central-Station Air-Handling Units

Optimize HVAC Takeoffs with MLEstimation: Seamless Integration with MasterFormat Standards

23 73 13
Modular Indoor Central-Station Air-Handling Units
23 73 23
Custom Indoor Central-Station Air-Handling Units
23 73 33
Indoor Indirect Fuel-Fired Heating and Ventilating Units
23 73 33.13
Indoor Indirect Oil-Fired Heating and Ventilating Units
23 73 33.16
Indoor Indirect Gas-Fired Heating and Ventilating Units
23 73 39
Indoor, Direct Gas-Fired Heating and Ventilating Units

Integrate your CRM with other tools

Lorem ipsum dolor sit amet, consectetur adipiscing elit lobortis arcu enim urna adipiscing praesent velit viverra sit semper lorem eu cursus vel hendrerit elementum morbi curabitur etiam nibh justo, lorem aliquet donec sed sit mi dignissim at ante massa mattis.

  1. Neque sodales ut etiam sit amet nisl purus non tellus orci ac auctor
  2. Adipiscing elit ut aliquam purus sit amet viverra suspendisse potenti
  3. Mauris commodo quis imperdiet massa tincidunt nunc pulvinar
  4. Adipiscing elit ut aliquam purus sit amet viverra suspendisse potenti

How to connect your integrations to your CRM platform?

Vitae congue eu consequat ac felis placerat vestibulum lectus mauris ultrices cursus sit amet dictum sit amet justo donec enim diam porttitor lacus luctus accumsan tortor posuere praesent tristique magna sit amet purus gravida quis blandit turpis.

Commodo quis imperdiet massa tincidunt nunc pulvinar

Techbit is the next-gen CRM platform designed for modern sales teams

At risus viverra adipiscing at in tellus integer feugiat nisl pretium fusce id velit ut tortor sagittis orci a scelerisque purus semper eget at lectus urna duis convallis. porta nibh venenatis cras sed felis eget neque laoreet suspendisse interdum consectetur libero id faucibus nisl donec pretium vulputate sapien nec sagittis aliquam nunc lobortis mattis aliquam faucibus purus in.

  • Neque sodales ut etiam sit amet nisl purus non tellus orci ac auctor
  • Adipiscing elit ut aliquam purus sit amet viverra suspendisse potenti venenatis
  • Mauris commodo quis imperdiet massa at in tincidunt nunc pulvinar
  • Adipiscing elit ut aliquam purus sit amet viverra suspendisse potenti consectetur
Why using the right CRM can make your team close more sales?

Nisi quis eleifend quam adipiscing vitae aliquet bibendum enim facilisis gravida neque. Velit euismod in pellentesque massa placerat volutpat lacus laoreet non curabitur gravida odio aenean sed adipiscing diam donec adipiscing tristique risus. amet est placerat.

“Nisi quis eleifend quam adipiscing vitae aliquet bibendum enim facilisis gravida neque velit euismod in pellentesque massa placerat.”
What other features would you like to see in our product?

Eget lorem dolor sed viverra ipsum nunc aliquet bibendum felis donec et odio pellentesque diam volutpat commodo sed egestas aliquam sem fringilla ut morbi tincidunt augue interdum velit euismod eu tincidunt tortor aliquam nulla facilisi aenean sed adipiscing diam donec adipiscing ut lectus arcu bibendum at varius vel pharetra nibh venenatis cras sed felis eget.

MasterFormat Division 23 73 00: Indoor Central-Station Air-Handling Units

MasterFormat Division 23 73 00 outlines the specifications for indoor central-station air-handling units (CSAHUs). These units are the beating heart of many large building HVAC systems, responsible for conditioning and distributing air to maintain a comfortable and healthy indoor environment. Understanding CSAHUs, their function, and key considerations for specification and installation is crucial for anyone involved in the design, construction, or maintenance of commercial buildings.

What is an Indoor Central-Station Air-Handling Unit?

An indoor central-station air-handling unit is a large, pre-assembled piece of HVAC equipment consisting of various components housed within a cabinet or enclosure. These components work together to treat and distribute conditioned air throughout a building. Unlike smaller, localized units, CSAHUs are designed to handle high air volumes and serve multiple zones or even an entire building from a central location.

How does an Indoor Central-Station Air-Handling Unit Work?

Here's a breakdown of the typical air handling process within a CSAHU:

  1. Air Intake: The unit draws in return air from the building and/or fresh outdoor air through an intake duct.
  2. Filtration: Air passes through filters of varying efficiencies to remove dust, pollen, and other airborne contaminants.
  3. Heating/Cooling: Depending on the season and desired temperature, the air is either heated by a heating coil (hot water, steam, or electric) or cooled by a cooling coil (chilled water or refrigerant).
  4. Humidity Control: A humidifier or dehumidifier may be integrated to regulate moisture levels in the air.
  5. Fan Section: A powerful fan propels the conditioned air through the ductwork.
  6. Distribution: The conditioned air is distributed throughout the building via a network of supply ducts and diffusers, delivering comfortable and healthy air to occupied spaces.

Where are Indoor Central-Station Air-Handling Units Commonly Used?

Due to their ability to handle large air volumes, indoor CSAHUs are commonly found in commercial, institutional, and industrial buildings, including:

  • Office buildings
  • Hospitals
  • Schools and universities
  • Shopping malls
  • Hotels
  • Manufacturing facilities

What are Installation Best Practices for Indoor Central-Station Air-Handling Units?

Proper installation is essential for efficient and long-lasting CSAHU performance. Here are some key best practices:

  • Location: Choose a location that provides adequate space for maintenance access, considers noise levels, and minimizes ductwork length.
  • Support: Ensure the unit is properly supported on a level platform or structural steel frame.
  • Ductwork Connections: Use flexible connections to minimize vibration transmission and allow for thermal expansion and contraction.
  • Electrical Connections: Follow all applicable electrical codes and ensure proper grounding and overcurrent protection.
  • Control Systems: Integrate the unit with the building automation system (BAS) for efficient control and monitoring.
  • Commissioning: Thoroughly test and balance the system after installation to verify proper airflow, temperature control, and overall performance.

What are the Top Manufacturers for Indoor Central-Station Air-Handling Units?

The HVAC industry includes numerous manufacturers specializing in CSAHUs. Some of the most reputable and well-known brands include:

  • Carrier
  • Trane
  • York
  • Daikin
  • McQuay
  • Lennox

Conclusion

Indoor central-station air-handling units are essential components of many large building HVAC systems. Understanding their specifications as outlined in MasterFormat Division 23 73 00, along with their functionality, installation best practices, and leading manufacturers, is vital for ensuring optimal indoor air quality, comfort, and energy efficiency in commercial and institutional settings. Consulting with qualified HVAC professionals during the design and construction phases is crucial for selecting the right CSAHU for a building's specific needs and ensuring its long-term, reliable operation.

Unlock Growth with Faster Takeoffs Today.